Eclipse Systems,
Inc. Compression System - Borrowed Lite Frame
Instructions
| 1) CUT HEAD COMPONENTS OF
GLAZING RAIL TO EXACT FINISH DIMENSION. PLACING HEAD COMPONENT ON
GROUND, INSTALL CORNER CLIP ON EACH END OF RAIL USING 1/2" SELF
TAPPING PAN HEAD SCREWS |

|
|
2) MAKE SURE "NOTCH" IN CLIP IS SECURED TIGHTLY AGAINST HEAD RAIL COMPONENT.
INSTALL HEAD RAIL INTO ROUGH OPENING. |
| 3) CUT LEG COMPONENTS OF
GLAZING RAIL TO EXACT FINISH DIMENSIONS. NOTCH TOP END OF RAIL AS
SHOWN. |

|
| 4) SECURE VERTICAL GLAZING
RAIL SLIDING CORNER CLIP FROM HEAD COMPONENT INTO GLAZING POCKET IN
VERTICAL LEG. WITH CORNER AND GLAZING POCKETS ALINED SECURE WITH
1/2" SELF TAPPING PAN HEAD SCREWS THROUGH CLIP INTO EACH VERTICAL
LEG. |

|
| 5) CUT SILL & STOP
COMPONENTS TO EXACT FINISH DIMENSION. FOR FLOOR MOUNT ATTACH A
SECTION OF GLAZING SNAP-IN, UPSIDE-DOWN, TO THE FLOOR. INSTALL
CORNER CLIP ON EACH END OF SILL AS IN STEP 1. SLIP SILL OVER WALL
(OR SNAP-IN PIECE). SET GLASS WITH WET GLAZING COMPOUND AND INSTALL
STOP. |
 Floor Mount
 Wall Mount
|
|
Eclipse Systems, Inc., 943 Hanson
Court, Milpitas, CA 95035 - Ph (408) 263-2201 - Fax (408)
263-2206
| |